Unbalanced Magnetic Pull in Dual Three-Phase Machine

Avtorji

Klemen Drobnič
Univerza v Ljubljani, Fakulteta za elektrotehniko
https://orcid.org/0000-0002-2444-2327
Rastko Fišer
Univerza v Ljubljani, Fakulteta za elektrotehniko
https://orcid.org/0000-0002-0740-4775

Kratka vsebina

This paper examines the emergence of unbalanced magnetic pull (UMP) in dual three-phase permanent magnet synchronous machines (DTM) during post-fault (PFO) and synthetic loading operation (SLO). Through FEM (finite element method) simulations, the paper reveals that UMP arises due to interactions between field harmonics with differing spatial orders, specifically the 4th and 5th harmonics during PFO and SLO. The presence of both odd and even harmonics in the machine's field spectrum is identified as a critical factor in UMP generation. The simulation results confirm that while UMP in DTM increases bearing stress and reduces lifespan, it does not compromise mechanical integrity, providing insights for machine design and control strategies under PFO and SLO.

Biografije avtorja

Klemen Drobnič, Univerza v Ljubljani, Fakulteta za elektrotehniko

Ljubljana, Slovenija. E-pošta: klemen.drobnic@fe.uni-lj.si

Rastko Fišer, Univerza v Ljubljani, Fakulteta za elektrotehniko

Ljubljana, Slovenija. E-pošta: rastko.fiser@fe.uni-lj.si

Prenosi

Izdano

14.05.2025

Kako citirati

Unbalanced Magnetic Pull in Dual Three-Phase Machine. (2025). In XXVIII. Symposium Electromagnetic Phenomena in Nonlinear Circuits (EPNC 2024): Conference Proceedings (pp. 223-228). Univerzitetna založba Univerze v Mariboru. https://press.um.si/index.php/ump/catalog/book/963/chapter/484